OutageMatch / Method
How we calculate, and where the numbers come from
OutageMatch answers one question: which portable power stations can run the devices you pick for as long as your outage lasts. This page lists every formula and assumption behind the answer, so you can check it or disagree with it.
Who makes this
OutageMatch is an independent site: no manufacturer pays to be listed or ranked. It earns a commission from Amazon when you buy through a link, and that is its only income. Stations are ordered by how closely they fit your setup, never by commission.
The calculation
Devices that cycle around the clock (refrigerator, router, sump pump) are counted by their total hours on per day, spread over the whole outage. Devices used at set times (CPAP, lights, TV) are counted by their hours per day for each full day, plus up to that many hours in a partial day.
Every result has a "Show the math" link with these three checks worked out for that station.
Default values
These are starting points. Every one can be changed in the finder, and your own device's label is always better than our default.
| Item | Our default | Why |
|---|---|---|
| Inverter efficiency | 0.85 | The factor most published sizing guides use. They range from 0.80 to 0.90. |
| Refrigerator | 150 W, 10 h/day, 1,200 W startup | 1,500 Wh a day. Manufacturer guides put home refrigerators between 0.9 and 2.2 kWh a day. The EnergyGuide label is more exact: kWh per year x 1,000 / 365. |
| CPAP | 60 W with heated humidifier, 40 W without, 8 h | Published figures run from about 10 W for a bare machine to 60 W or more with humidifier and heated hose. |
| Wi-Fi router | 15 W, 24 h | Guides give 10 to 25 W. |
| LED lights | 10 W, 5 h | One or two bulbs. Raise it for a whole room. |
| Phone charging | 10 W, 2 h | About 20 Wh, one to two full charges. |
| Laptop | 50 W, 4 h | Virginia Cooperative Extension lists 50 W. |
| TV | 100 W, 3 h | Guides give 80 to 150 W depending on size. |
| Sump pump | 800 W, 5 h/day, 2,000 W startup | A 1/3 HP pump running 10 to 15 minutes an hour in a storm. In dry weather it runs far less. |
| Solar | 4 sun hours, 75% of panel rating | A station counts as solar-sustained only if one day of sun refills one day of use and the battery alone lasts the hours without sun. |
Sources
- Station specs (capacity, continuous output, surge, battery chemistry, weight, solar input, expansion): each manufacturer's own product page or manual, linked from every row as "Manufacturer specs". Last checked November 19, 2026.
- Outage length: U.S. Energy Information Administration, average interruption hours per customer in 2024.
- Appliance watts and refrigerator cycling: Virginia Cooperative Extension, publication 2901-9014.
- Refrigerator annual consumption: the EnergyGuide label on your own appliance, and ENERGY STAR.
- Default device values were cross-checked against manufacturer sizing guides, for example Anker's 3-day backup guide and refrigerator guide.
What this does not account for
- The station's own idle draw. An inverter left on uses power even with nothing plugged in, which matters most for small loads over several days.
- Battery age and cold. Capacity falls as a battery ages and in low temperatures.
- 240 V loads such as well pumps, dryers or central air. The finder covers 120 V household devices.
- Surge behavior beyond the published rating. Makers do not all measure surge the same way, and a motor in poor condition can pull more than its nameplate suggests.
- Every model. We track 82 stations and list the 44 that Amazon sells new on their own and whose surge rating we could confirm. Some makers do not publish one and some sites blocked our checks.
- Prices. Each row links to that model's own Amazon page for the current price.
Medical devices: treat every figure here as an estimate. Test your equipment on the power station before an outage and follow your device maker's instructions.